Description
I Treatment theory
1. CO2 Fractional laser is the most advanced conceptual fractional CO2 skin peeling laser system with a wavelength of 10600nm. In addition to its fine skin-peeling effect, it can effectively penetrate the laser beam into the dermis. It is the most beneficial skin recovery system and can achieve the long-term effect of collagen remodeling as well as improvement of aged skin conditions due to exposure to light. It can be very safely applied to various types of scars compared to the existing 100% total layer skin peeling lasers (CO2 or Er: YAG). In addition, it does not require a long period of recovery or side effects. It can remodel various types of deformed scars and skin tissue very effectively.
2. Laser machine has 2 kinds of operating system; One is fractional CO2 laser for scars removal, skin rejuvenation, stretch marks removal.
3. And another system is for vaginal rejuvenation. It has 2 probes. On the probe there is 2940 lens, so it is mixture of 10600nm & 2940nm light. This system only has 2 shapes: Round & square.
2. Acne scar removal, scars and surgery scars, dermabrasion, Remove intractable chloasmas and pigmentation, etc
3. CO2 laser cutting in aesthetic surgery: Mainly used for cutting on blepharoplasty, skin tags and ingrown nails, compound nevus and intra dermal nevus, etc

-RF driver fractional CO2 laser
-10600 nm wavelength
-50 Watts max power
-Ellipse scan, rectangle scan, triangle scan
-650nm ruby laser indicator
-Wind cooling system
-Compared with traditional fractional CO2 laser, this model has steady energy output and dramatic treatment results. What's more, you do not need to change the CO2 tube at all.





Using the perfect wavelength and heat ratio of co2 laser, the powerful heat can make the collagen fibers, elastic fibers, reticular fibers, and organic matrix in the vaginal mucosa proliferate and remodel. The principle of the microvasculature of co2 makes vaginal revascularization. The blood flow is increased, the cell function is active, and the vaginal tightening, the secretion effect is enhanced, the sensitivity is improved, and the vagina is restored to a young and healthy state.
-Vaginal tightening - the principle of matrix and collagen production
The CO2 laser can induce heat shock response (HSR), which can produce heat shock protein (HSP). Heat shock protein 70 can be transformed into growth factor β under laser irradiation. TGF-β plays a key role in the inflammatory reaction and fibrosis reaction. It induces the production of collagen and extracellular matrices by cells. Intimate youth laser acts on the vaginal mucosa and muscle layer, stimulating collagen fibers in the lamina propria and muscle layers, and elastic hyperplasia, elastic fibers, reticular fibers, and organic matrix, which make the vagina tighten.
Collagen remodeling and the role of incentives
1: Acute thermal injury stage (48-72 hours)
Edema - the chemical medium released (a healing mechanism) - collagen contraction
2: Proliferation period (30 days)
Fibroblast proliferation - new matrix molecules increase - new collagen fiber formation
3: Reconstruction period
The disappearance of inflammatory infiltration - mature collagen fiber proliferation and collagen fiber remodeling - new elastic fiber increase
-Improve tightness and lubricity - the principle of co2 laser revascularization
The microvascular stimulation of the co2 laser causes vasodilation and increased blood flow, which in turn increases cellular oxidation and nutrients, and activates cellular functions.
Increased sensitivity
The complete, dynamic response of the vaginal blood vessels to sexual stimulation plays a key role in the excitatory phase of the genital response. Reducing vasodilation can lead to sexual problems, especially genital arousal disorders, and the sensitivity is reduced. Accompanied by insufficient vaginal lubrication or even dryness.
2. Increased lubricity
The mitochondria release ATP increased, the cell function is active, the vaginal mucosa secretion is enhanced, the color becomes lighter, and the lubrication effect is enhanced.
1. The ideal laser wavelength can be absorbed by micron-sized tissue on the mucosa to avoid thermal damage to deep tissues or organs.
2. The laser energy is output in the form of optimized intermittent intervals and short pulses, which can avoid the formation of high temperature on the skin surface and cause thermal damage, while the surface layer of several hundred microns thick in the mucosa tissue forms a uniform thermal effect.
3. Use Smooth Smooth mode to treat vaginal mucosa tissue in a feather-like, non-invasive mode without bleeding, as this mode allows precise temperature control to avoid tissue damage.
Gold 360 ring launch technology
The laser is applied to the vaginal wall in a circular illumination mode by means of a gold-plated 360° reflector. Instead of touching the vaginal wall, the laser energy is applied evenly and uniformly to the entire vaginal segment. This technology makes vaginal laser tightening technology easier to operate, shorter treatment time, and higher safety.
The co2 laser has a perfect ratio of exfoliation and thermal effect, which stimulates the proliferation of collagen fibers and elastic fibers, and has a strong remodeling effect and a good tightening effect. Due to the principle of co2 laser-stimulated angiogenesis, vaginal blood flow can be increased, cell function is active, and vaginal sensitivity and lubrication are increased. According to research, the vaginal pH can be changed to normalize the vaginal flora.
-Painless, safe, short treatment time
1. The private youth laser preserves normal mucosal tissue between the beam spots, making the heat diffusion more uniform and avoiding thermal damage.
2. The treatment is simple and fast. Because the private youth laser is effective, the treatment is safer, the patient is highly accepted, and the vaginal problem can be changed in all directions to restore the \"young\" state.
3. The operation is simple, the treatment is efficient and safe, there is no need to rest after surgery, and it does not affect the work.
4. It can treat all parts of the body, with good effect, wide source of disease, and rich income.
5. The latest international technology, a light-based beauty method with a large amount of clinical experience.
6. This machine is composed of two parts: the main unit and the handle. The company maintains the original performance of the neodymium glass laser but is compact and integrated into the handle. This not only saves the loss of optical fiber transmission but also is very convenient for maintenance.
7. The main components are imported from abroad, and a lot of innovations have been made in the structure, and the technical performance has reached the international advanced level. When changing the lamp, you only need to send the handle back to the manufacturer, no need to change the host.
8. Non-exfoliating treatment, no pain, short time, no adverse reactions, especially suitable for young and middle-aged people.
9. This unit has three different beam density microbeam array outputs. They can be easily replaced on the handle. For each point density, a variety of point energy levels are set to provide tailor-made treatment for different lesions, so as to achieve the most satisfactory therapeutic effect.
1 shrinking: fast tightening, lasting tightness, and tightness increased by 60%
2 Meiyin: lighten the pigment, beautify the degree of tenderness of the labia by 70%.
3 Run Yin: Improve secretion, eliminate dryness, and increase lubrication by 80%.
4 Yang Yin: Deep anti-aging, prevent aging youngness increased by 80%.
5 Improve sensitivity.
6 private and healthy, balance ph, improve the internal environment.
1. Women who have had a childbearing experience.
2, sex experienced women for more than 3 years.
3, sex women are frequent.
4. Women who have aborted people.
5. Women with gynecological problems.
6, women with low or high sex orgasm.
1. Various scars (surgical scars, burn scars, burn scars)
2. Remove pigmentation lesions (freckles, sun spots, age spots, sun spots, chloasma, etc.)
3. Remove stretch marks.
4. Complete skin rejuvenation (rejuvenation, firming, shrinking pores, nodular acne)
5. Vascular lesions (capillary hyperplasia, rosacea)
6. Remove false, true wrinkles
7. Get rid of acne
Burnt
The maximum laser power output of the instrument can reach 40 watts, which can cause 3-degree burns without focusing. Therefore, we should pay enough attention to.
-The harm of reflection and direct injection to the human eye
The instrument outputs a visible red semiconductor laser and an invisible co2 laser, which are harmful to the human body.
Do not look directly at the red semiconductor laser at all times, even if it does not cause burns to the human eye, but it also has a certain degree of damage.
The h2 laser has a very high hazard. Direct exposure to the human eye can lead to blindness and is unrecoverable. Operators should be careful.
Since the surface of an object, especially a smooth metal or glass surface, can be mirrored to reflect light, it is important to note that the path through which the laser passes should remove such objects or surfaces that may cause reflection. In other words, do not illuminate the laser with objects that reflect light, to prevent the laser from being reflected or scattered from harming the human body.
-Flammable and explosive
Do not use this laser instrument on the site with inflammable or explosive materials. Do not place or store flammable or explosive materials around the instrument. Flammable and explosive materials include gasoline, alcohol, some narcotics, some solvents, desiccants, ointments, synthetic resins, etc.
-Safe operation steps
First, before surgery ‘
1.Keep the instrument surface clean.
2.Get the instrument key.
3.Ask the surgeon how to arrange the instrument and the patient\'s position.
4.Put a laser warning sign on the eye-catching position.
5.To use a general anesthetic, prepare a wet towel for the patient.
6.Have all the necessary equipment and tools ready.
7.Check that the instrument is working properly.
8.After plugging the switch key into the instrument, the key is plugged in and power on. The instrument should be self-test first and enter the standby state after selecting the working mode.
9.If necessary, press the SET button to reset the operating parameters.
10.Check the same light path.
11.Press the SET button to return to the standby state or turn off the instrument until the computer is turned on.
Second, after the operation is completed
1.Shut down and remove the instrument.
2.Remove the switch key and keep it in a safe place.
3.Place the light guide arm in the normal position.
4.If necessary, remove optical accessories and other tools for cleaning or disinfection.
1 X Guide light arm
1 X Fractional laser head
1 X Pulse head
1 X Tightening head
1 X Footswitch
1 X Power cable
2 X Key